LFA 1000 - Thermal Conductivity Analyzer
Product Description
Information of the thermo physical properties of materials and heat transfer optimization of final products is becoming more and more vital for industrial applications. Over the past few decades, the flash method has developed into the most commonly used technique for the measurement of the thermal diffusivity and thermal conductivity of various kinds of solids, powders and liquids.
The Linseis LFA 1000 Laser Flash is the most modular and precise Instrument for the determination of Thermal Diffusivity, Conductivity and Specific Heat Values. Its sample robot for up to 6 Samples at the same time allows unbeaten turnaround times. The three user exchangeable furnaces allow measurements from -125 up to 1600°C.
A number of different sample holders for applications such as solids, liquids, melts and slags are available. The compact design allows the separation of hardware and electronics as well as the installation under a hood for nuclear applications.
The application measurement: Application Example: Copper/Aluminum, reference material Pyroceram 9606 and Isotropic Graphite (AIST).
Specifications
Model | LFA 1000 |
---|---|
Temperature range | –100 up to 500°C RT up to 1250 / 1600°C |
Heating rate | 0.01 up to 20°C |
Thermal Diffusivity | 0.01 up to 2000 mm2 /s |
Thermal Conductivity | 0.1 up to 4000 W/(m•K) |
Accuracy | Thermal diffusivity ± 2.4% Specific Heat ± 5% |
Repeatability | Thermal diffusivity ± 1.9% Specific Heat ± 3% |
Flash source | Laser Nd:YAG 25 J/pulse Pulse width: 0.05 up to 5 ms variable pulse energy: software controlled |
IR-detector | InSb: RT up to 1250 / 1600°C MCT: –100 up to 500°C |
Atmosphere | inert, oxidizing, reducing, vacuum |
Vacuum | up to 10-5 mbar |
Data acquisition | 2 MHz |
Gas control | manual or MFC gas dosing systems |
Sample holders | for round, square, powders, pastes, laminates, samples and mechanic pressure |
Sample numbers | up to 18 samples |
Model | LFA 1000 |
---|---|
Temperature range | -125 up to 500°C |
RT up to 1250°C | |
RT up to 1600°C | |
Pulse source Nd | YAG Laser 25 J/pulse |
Measurement of temp. rise | Contact less with IR detector (InSb or MCT) |
Measuring range th. diffusivity | 0.01 mm2/s ... 1000 mm2/s |
Measuring range th. conductivity | 0.1 W/mk ... 2000 W/mK |
Sample dimensions | round samples 10, 12.7 ... 25.4 mm diameter square samples 10x10 mm |
Sample Thickness | 0.1 mm ... 6 mm |
Nr. of Samples | Sample robot for up to 6 samples |
Sample holder | metal/SiC/Graphite |
Sample holder for liquids | available |
Atmospheres | inert, oxidizing, reducing, vacuum |
Electronics | Integrated |
Interface | USB |